Innovations

GROUNDBREAKING IMPLANT DESIGNS FOR A SEAMLESS CLINICAL WORKFLOW

A machined and anodized collar design can be particularly advantageous when managing uneven ridges.
By minimizing rough surface exposure in the collar region, this design supports healthier soft-tissue interaction, reduces plaque accumulation, and facilitates improved hygiene access—key factors in peri-implantitis prevention.

Hybrid Surface Implants

Implant_Closeup_SP3712-black-background-2.jpg
Mask-Group-2.png

Machined anodized neck surface

Machined anodized neck surface roughness of 0.6 ± 0.2 µm (moderately rough anodized) is biocompatible and osseoconductive, promoting favorable bone healing responses1.

Roughness-of-apex-3.png

Rough body surface

The surface roughness of the body is 1.5–2.3 µm, shown better outcomes in terms of bone-implant contact compared to both smooth and excessively rough surfaces2.

Introducing Vertical Flexibility

1mm supracrestal placement creates a zone of undisturbed tissue attachment
Accommodate uneven ridges and avoid exposure of rough surface
Bone-level placement for aesthetic applications

What are the benefits of Vertical Flexibility?

BONE LEVEL IMPLANT WITH VERTICAL FLEXIBILITY

$125

Strength
Industry Standard 45° lead-in Conical Connection (Niznick US Patent #4,960,381) maximizes wall thickness on narrow implants

Value
Two Platform Diameters (3.5mmD & 4.5mmD) optimize emergence profile

Flexibility
1mm added to the standard lengths provides vertical flexibility for placement in uneven ridges and extraction sockets

Full-Arch Application-Specific Implants

A PARADIGM SHIFT IN FULL-ARCH TREATMENT

$150

Simplicity
One Prosthetic Platform

Value
Extender Converts to MUA and OD Abutment with $25 Screw Reduced Prosthetic Inventory – only four Screws for All-on-4 Case

Flexibility
Full Range of Straight, Angled, ASC and Temporary Abutments

friction-fit-v3-2025.png
screw-converts-mua-v3-2025.png
standard-mua-v3-2025.png

FROM OVERDENTURE TO FIXED FULL‑ARCH WITH ONE SYSTEM

$135

Strength
One-Piece Implant with Hybrid Surface

Value
2mm Extender for height range of 1-5mm

Flexibility
Dual Function Platform: Locator compatible for overdentures and internal connection for conversion to fixed full-arch

Implant Patents

Clinical Images

References:

1. Milleret V, Lienemann PS, Gasser A, Bauer S, Ehrbar M, Wennerberg A. Rational design and in vitro characterization of novel dental implant and abutment surfaces for balancing clinical and biological needs. Clin Implant Dent Relat Res. 2019 Mar;21 Suppl 1:15-24. doi:10.1111/cid.12736. Epub 2019 Feb 27. PMID: 30809940.
2. Lagdive SS, Vasani A, Madhad V, Tulsi SPS, Panda A, Gupta SP, Patadiya HH, Lunkad H. In Vitro Analysis of Bone Response to Different Implant Surface Roughness. J Pharm Bioallied Sci. 2025 Jun;17(Suppl 2):S1104-S1106. doi: 10.4103/jpbs.jpbs_1651_24. Epub 2025 Jun 18. PMID: 40655589; PMCID: PMC12244635.